首页> 外文会议>International Conference on Environment and Electrical Engineering >Switching panels for complete utilisation of battery banks in multi-level inverters for PV systems
【24h】

Switching panels for complete utilisation of battery banks in multi-level inverters for PV systems

机译:配电板,用于光伏系统多级逆变器中电池组的完全利用

获取原文

摘要

Multi-level inverter are preferred choice for PV system applications for past decade because of its better harmonic profile and low dv/dt. Along with these advantage it suffers from power balancing issues which are caused by uneven partial shading. This paper proposes a technique to minimize the difference in discharge levels of upper and lower battery banks. The proposed topology involves selection of isolated panels through optimization by considering irregularity of roof top and worst case conditions. In addition, a control strategy is developed for switching isolated panels depending on difference in discharge levels. This topology makes the system to run longtime by complete utilization of battery banks. The proposed topology is verified using three level topology using cascaded bridge configuration accompanied by two battery banks in MATLAB/SIMULINK environment.
机译:在过去的十年中,多电平逆变器是光伏系统应用的首选,因为它具有更好的谐波分布和较低的dv / dt。伴随着这些优点,它还遭受了由不均匀的局部阴影引起的功率平衡问题。本文提出了一种使上下电池组放电水平差异最小的技术。拟议的拓扑涉及通过考虑屋顶的不规则性和最坏情况的条件来通过优化来选择隔离面板。另外,开发了一种控制策略,用于根据放电水平的差异切换隔离的面板。这种拓扑结构可以通过充分利用电池组来使系统长时间运行。在MATLAB / SIMULINK环境中,使用三级拓扑,级联桥配置以及两个电池组,对提出的拓扑进行了验证。