Power transmission using HVDC transmission technology has existed for several years. As part of the design specification for such schemes, transmission line and substation insulator selection is crucial to ensure good operational performance. Leakage current may occur on insulators due to contamination, ageing of insulation materials and aggressive weather conditions, amongst others. If not mitigated, these currents can lead to line faults which occur as flashover of the insulator and the degradation of the insulator material. Monitoring leakage current on alternating current transmission lines may be accomplished using current transformer devices. However, this cannot be used in direct current transmission lines due to static magnetic fields. Toughened glass insulators are generally preferred for HVDC schemes, but composite insulators are proving to be cost-effective alternatives. However, because of its relatively new application in HVDC schemes, little has been published relating to operational data on typical leakage current magnitudes, waveforms and consequential effects thereof. ESKOM currently operates and maintains the South African sections of the Cahora Bassa HVDC scheme. At present, the utility does not have an in-situ, non-intrusive solution for monitoring the leakage currents on this scheme. This paper presents an overview of leakage current and the options available for measuring it. In-situ and non-intrusive sensors have the benefit of being used for real time monitoring as well as for live line work.
机译:使用HVDC输电技术的输电已经存在了几年。作为此类方案的设计规范的一部分,传输线和变电站绝缘子的选择对于确保良好的运行性能至关重要。除其他因素外,由于污染,绝缘材料的老化和恶劣的天气条件,绝缘子上可能会发生漏电流。如果不加以缓解,这些电流会导致线路故障,这些故障会随着绝缘子的闪络和绝缘子材料的劣化而发生。可以使用电流互感器设备来监视交流输电线路上的泄漏电流。但是,由于静磁场,不能在直流输电线路中使用。对于HVDC方案,通常首选钢化玻璃绝缘子,但事实证明,复合绝缘子是具有成本效益的替代方案。然而,由于其在高压直流输电方案中的相对较新的应用,有关典型泄漏电流大小,波形及其后果的操作数据的报道很少。 ESKOM目前运营和维护Cahora Bassa高压直流输电计划的南非部分。当前,该公用事业公司还没有现场,非侵入式解决方案来监视此方案中的泄漏电流。本文概述了泄漏电流及其测量方法。原位和非侵入式传感器的优势在于可用于实时监控以及实时线路工作。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号