首页> 外文会议>International Conference on Wearable and Implantable Body Sensor Networks >Evaluation of Bioimpedance Spectroscopy for the Monitoring of the Fluid Status in an Animal Model
【24h】

Evaluation of Bioimpedance Spectroscopy for the Monitoring of the Fluid Status in an Animal Model

机译:生物敏捷光谱法监测动物模型中流体状态的评价

获取原文
获取外文期刊封面目录资料

摘要

This study investigates the feasibility of using bioelectrical impedance measurements to rev{detect} the body fluid status. The multi-frequency impedance measurements were performed in combination with an animal experiment with five female pigs. For this purpose, the fluid balances of these animals, which were connected to an extracorporeal membrane oxygenation, were recorded. The ECMO circuit needs a high blood flow from the venous system and in order to avoid vasoconstriction in the femoral vein, blood-thinning infusions were injected. The quantity of injected fluid and the quantity of urine were recorded to monitor the fluid balance of each animal. These balances were compared with the intracellular and extra cellular tissue resistance, which was measured by bioelectrical-impedance spectroscopy. The experimental results strongly support the clinical benefit of the BIS for the assessment of changes in the hydration status.
机译:本研究调查使用生物电阻抗测量来旋转{检测}体液状态的可行性。 多频阻抗测量与具有五个雌性猪的动物实验组合进行。 为此目的,记录了这些动物的流体平衡,其与体外膜氧合有影响。 ECMO电路需要来自静脉系统的高血流,以避免股静脉中的血管收缩,注射血液稀释剂。 记录注射流体的量和尿量的量以监测每只动物的流体平衡。 将这些平衡与细胞内和额外的细胞组织抗性进行比较,其通过生物电解光谱法测量。 实验结果强烈支持BIS的临床益处,以评估水合地位的变化。