【24h】

CHARRING RATE OF TIMBER IN NATURAL FIRES

机译:天然木材的木材收费率

获取原文

摘要

A total of 32 glulam beams have been fire tested using three different fire curves and with different load levels.The aim of the project was to study the load bearing capacity and the charring rate under different fire curves and to gather data as to the variation of the response of timber beams in fire.Prior to the fire tests, the 32 beams were selected out of a total sample set of 45 glulam beams which was subject to reference testing and then grouping into 5 approximately equal groups in terms of mean and standard deviation of stiffness.One of these groups was subject to static bending tests until failure and was deemed to be representative of the strength of all of the other groups.During the fire tests the charring rate was determined from temperature measurements made at different depths and locations in the tested beams, as well as by inspection of the residual cross section after the fire test.This paper reports on the test programme as well as the measured charring rates during the fire tests.The results show that the fire intensity has a major influence on the charring rate as well the variance in charring rate over the course of the fire.The charring rate also varies with time during the fire exposure.Other measurements and analysis have been conducted although they are not the scope of this paper.
机译:共有32条胶合木梁通过三种不同的着火曲线和不同的载荷水平进行了耐火测试。该项目的目的是研究不同着火曲线下的承载能力和炭化率,并收集有关载荷变化的数据。在燃烧测试之前,从45个胶合木梁的总样本集中选择了32个木梁,并对其进行了参考测试,然后按照均值和标准差将其分为5个大致相等的组这些组中的一组经受静态弯曲测试直至失效,并被认为代表了所有其他组的强度。在燃烧测试期间,炭化率是根据在不同深度和位置进行的温度测量确定的测试梁,以及通过耐火测试后检查剩余横截面。本文报告了测试程序以及测得的杜林炭化率结果表明,着火强度对着火率以及着火过程中着火率的变化有很大的影响,着火率也随着火时间而变化。其他测量和分析尽管它们不在本文讨论范围之内,但已经进行过。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号