【24h】

MEMBRANE ACTION OF TIMBER FIBRE REINFORCED CONCRETE COMPOSITE FLOOR IN FIRE

机译:木材纤维增强混凝土复合地板在火灾中的膜作用

获取原文

摘要

In the two last years, the furnace tests were performed on two full-size floor specimens at the Czech Technical University in Prague.Both floor specimens were 4.5 m long and 3 m wide, consisting of 60 mm fibre concrete topping on plywood formwork, connected to GL floor joists and were subjected the standard fire for over 150 min./ 60 min.The floors were partially protected.The membrane effect of the floor was activated to maintain the global resistance of the floor.Based on the performed tests is prepared a numerical model of the timber fibre reinforced concrete floor slabs in fire.The experimental research results that deal with the effect of membrane action of composite steel fibre reinforced floor slabs exposed to fire offers a new timber-concrete floor with subtle cross-section of timber beam.
机译:在过去的两年中,在布拉格的捷克技术大学对两个全尺寸地板试样进行了熔炉测试,两个地板试样长4.5 m,宽3 m,由60 mm纤维混凝土浇筑而成,覆盖在胶合板模板上,相连在GL地板托梁上进行了150分钟/ 60分钟的标准燃烧,地板得到了部分保护,激活了地板的膜效应以保持地板的整体抵抗力,并根据进行的测试制备了火灾下木纤维混凝土楼板的数值模型。处理火灾下复合钢纤维混凝土楼板的膜作用影响的实验研究结果,提供了一种新型的木梁混凝土截面细微的木梁地板。 。