The low-temperature hot-water floor radiant heating system could intermittently work without impacting the indoor thermal comfort conditions for occupants. According to the urban resident life work and rest mode and the change characteristics of indoor air temperature caused by intermittent operation of this system, the control strategies of the system of the urban residential building were proposed. The control strategies contained the average temperature adjustment of coil supply and return water and the time adjustment of system start/stop. In the different control strategies, the indoor air temperatures of the south room and the north room were analyzed by numerical simulation. The results indicated that to meet the thermal comfort requirements for most occupants, the north room needed to be heated about 18 h per day, while the south room only needed to be heated for 13-14 h per day.
机译:低温热水地板辐射供暖系统可以间歇工作,而不会影响居住者的室内热舒适条件。根据城市居民生活工作和休息方式,以及该系统间歇性运行引起的室内空气温度变化特点,提出了城市居民住房系统的控制策略。控制策略包括盘管给水和回水的平均温度调节以及系统启动/停止的时间调节。在不同的控制策略下,通过数值模拟分析了南房间和北房间的室内空气温度。结果表明,要满足大多数乘员的热舒适性要求,北房间每天需要加热约18小时,而南房间每天只需加热13-14小时。