For natural ventilation, setting upper vents of urban highway tunnel is one possible method for improving the environment and the outlet of the tunnel. In this present paper, one 1,000 m tunnel is chosen as the analysis object, according to the universal size of road tunnel. The relationship between the number of upper vents groups and pollutant dispersion in the tunnel was analyzed with aid of the subway environment simulation (SES) simulation software. The results show that the urban highway tunnel with upper vents can emit pollutant along the tunnel. Meanwhile, for the same quantity, total area of the vents and a certain vents spans, two vent groups are the best type of ventilation, from which about 50 % pollutant emission can be emitted. In addition, the single group is the worst type of ventilation, from which only 37 % pollutant emission can be emitted.
机译:对于自然通风,距离城市公路隧道的上通风口是改善隧道环境和出口的一种可能的方法。在本文中,根据道路隧道的普遍尺寸,选择一个1,000米的隧道作为分析对象。利用地铁环境模拟(SES)仿真软件,分析了隧道中上通风口组和污染物分散之间的关系。结果表明,带上通风口的城市公路隧道可以沿着隧道发出污染物。同时,对于相同的数量,通风口的总面积和某个通风口跨度,两个排气组是最佳的通风类型,可以发出约50%的污染物排放。此外,单一组是最糟糕的通风类型,从中只能发出37%的污染物排放。