首页> 外文会议>IET Renewable Power Generation Conference >Inter-turn fault detection in doubly-fed induction generators for wind turbine applications using the stator reactive power analysis
【24h】

Inter-turn fault detection in doubly-fed induction generators for wind turbine applications using the stator reactive power analysis

机译:使用定子无功功率分析的风力发电机双馈感应发电机匝间故障检测

获取原文

摘要

This paper proposes a new technique for the detection of inter-turn short circuit faults in the stator and rotor windings of doubly-fed induction generators. The proposed technique is based on the Fast Fourier Transform of the stator instantaneous reactive power. The effectiveness of the proposed diagnostic method to detect these faults is evaluated by extensive experimental tests that were performed for different generator operating conditions, namely for different values of the active and reactive power injected into the grid and different values of the rotor speed. The obtained results show that the proposed approach is appropriate for the identification and quantification of the faults under study.
机译:本文提出了一种检测双馈感应发电机定子和转子绕组匝间短路故障的新技术。所提出的技术基于定子瞬时无功功率的快速傅立叶变换。通过针对不同的发电机工况(即,注入电网的有功和无功功率的不同值和转子速度的不同值)进行的广泛实验测试,评估了所提出诊断方法检测这些故障的有效性。获得的结果表明,所提出的方法适用于所研究故障的识别和定量。