首页> 外文会议>IEEE Holm Conference on Electrical Contacts >Break arc duration characteristics of AgSnO2 contacts under magnetic field application with contact opening speeds in the range up to 200mm/s in DC load conditions
【24h】

Break arc duration characteristics of AgSnO2 contacts under magnetic field application with contact opening speeds in the range up to 200mm/s in DC load conditions

机译:AGSNO2触点在磁场施加下的AGSNO2触点的断裂持续时间特征,在直流负载条件下高达200mm / s的接触开口速度

获取原文

摘要

Break operations of AgSnO2 contact pairs were conducted in a DC inductive circuit (L=5.7mH) at 14V-11A and in a DC resistive circuit at 14V-13A under different contact opening speeds from 0.5 to 200 mm/s and with/without external magnetic field application in air. Break arc voltage waveforms were observed, and total break arc durations and metallic phase durations were determined based the observed arc voltage waveforms. After the experiments, averages for total arc durations as well as the metallic phase and gaseous phase (when observed) durations were calculated at each condition. The results show that increases in the contact opening speeds lead to reductions in metallic phase durations, while application of external magnetic field causes gaseous phases to become shorter.