摘要

Infrared thermography is widely used to monitor the health of electrical power connections in live electrical lines. Although thermal imaging is helpful in locating faulty connections, surface temperature measurement alone is a poor indicator for fault severity assessment. Furthermore, under low load or other adverse environmental situations, the technique may not provide sufficient information to identify electrical connections in the initial or even advanced phases of electrical failure. This limitation stems from the large difference between the temperature of overheated electrical contact spots in a failing electrical interface and the temperature of the external surfaces of the electrical joint. This paper reports the results of calculations, based on a simple computer model, that illustrate the differences between the temperature of an electrical interface and the external surface temperature of the connection.
机译:红外热成像技术广泛用于监视带电电线中的电源连接状况。尽管热成像有助于定位故障连接,但仅通过表面温度测量就不足以进行故障严重性评估。此外,在低负载或其他不利的环境情况下,该技术可能无法提供足够的信息来识别电气故障的初始甚至高级阶段中的电气连接。该限制源于失效的电接口中的过热电接触点的温度与电接头外表面的温度之间的巨大差异。本文基于一个简单的计算机模型报告了计算结果,该计算结果说明了电接口温度和连接的外表面温度之间的差异。