首页> 外文会议>European Microwave Conference >A novel concentration detection method of hydrogen peroxide using microwave cavity perturbation technique
【24h】

A novel concentration detection method of hydrogen peroxide using microwave cavity perturbation technique

机译:微波腔扰动技术新型过氧化氢浓度检测方法

获取原文
获取外文期刊封面目录资料

摘要

Since there has been no effort at all in using a microwave cavity resonator in the detection of hydrogen peroxide in water, we propose a simple detection method of hydrogen peroxide concentration based on the well-known microwave cavity perturbation technique for the TM mode at of a copper cylindrical cavity at 3.48 GHz. From the measurements, we found that the main parameters for cavity perturbation namely center frequency shifts and bandwidth (or quality factor Q) changes both exhibit strong correlation with the concentration.
机译:由于在使用微波腔谐振器在水中的过氧化氢检测中没有努力,因此基于A的众所周知的微波腔扰动技术提出了一种简单的过氧化氢浓度的检测方法3.48 GHz的铜圆柱腔。从测量开始,我们发现腔扰动即中心频率偏移和带宽(或质量因数Q)的主要参数变化都与浓度表现出强烈的相关性。