We have demonstrated a technique to replicate the worst case failure mode of a known implant failure. We believe that the proposed test setup can be used to benchmark various implant designs against known clinically successful UKRs. Ideally, the next step of our proposal would be to test the S&N implant in our model setup to establish an acceptable load, illustrating that the implants could survive the well-established 10 million cycles of fatigue loading. F1800 calls for a load of 900N based on the clinical failure of an implant replicated in a test setting. For an implant that is designed to support approximately 70% of the knee joint load, 630N would be a reasonable starting point.
机译:我们已经证明了一种复制已知植入物失败的最坏情况失效模式的技术。 我们认为,所提出的测试设置可用于对针对已知的临床成功的UKR进行基准测试各种植入物设计。 理想情况下,我们提案的下一步将是在我们的模型设置中测试S&N植入物,以建立可接受的负载,说明植入物可以在熟悉的1000万次疲劳负荷循环中存活。 F1800根据在测试设置中复制的植入物的临床失败来调用900N的负载。 对于设计用于支撑大约70%的膝关节载荷的植入物,630n将是合理的起点。