In conclusion, this test method was useful in testing abrasion resistance of the components in endovascular stent grafts. The abrasion resistance of both fabrics was lower in a wet environment compared to being tested dry. Additionally, the multifilament polyester fabric had better abrasion resistance than the monofilament polyester fabrics. The laser cut nitinol stent was more aggressive in creating holes and broken yams in both fabrics, while the regular nitinol stent wire caused more fabric strength loss. These conclusion have led to the recommendation of a new in vitro stent-graft abrasion test method for endovascular devices which include the use of this abrasion tester operating for 7,200 cycles (1 hour) under wet conditions and using the three endpoints described above.
机译:总之,该测试方法可用于测试血管内覆膜支架组件的耐磨性。与在干燥环境中进行测试相比,两种织物在潮湿环境中的耐磨性均较低。另外,复丝聚酯织物比单丝聚酯织物具有更好的耐磨性。激光切割的镍钛诺支架在两种织物上都更容易产生孔洞和折断的纱线,而普通的镍钛诺支架线会造成更多的织物强度损失。这些结论导致了对血管内装置的新的体外支架移植物磨损测试方法的推荐,该方法包括使用该磨损测试仪在潮湿条件下运行7200个周期(1小时),并使用上述三个端点。