首页> 外文会议>Southern Biomedical Engineering Conference >Design of Patient Testing Models for Cardiovascular Medical Device in Silico and In Vitro Assessment
【24h】

Design of Patient Testing Models for Cardiovascular Medical Device in Silico and In Vitro Assessment

机译:硅和体外评估中心血管医疗器械患者试验模型的设计

获取原文

摘要

Clinical evidence indicates that left ventricular assist device (LVAD) recipients present a diverse cohort of pathophysiology and cardiac functionality. The challenge of assuring device safety and proper performance in this patient set represents a challenge in both the range and resolution of the conditions. Furthermore, the cardiovascular systems of these individuals are highly susceptible to events that may trigger unsafe operating conditions for the LVAD: sudden postural change (e.g falling), drug induced tachycardia, etc. Developing appropriate computational design tools and reflective in vitro test system permits device designers to elucidate more liabilities in the design earlier in the development cycle. Conditions for a mock circulatory loop were sourced from clinical publications detailing the cardiovascular parameters determined for various patient classes and event sequences. The developed profiles for healthy adult, congestive heart failure adult, healthy geriatric, congestive heart failure geriatric, and healthy pediatric were designed. The profiles were developed from published clinical metrics and parameter estimations of PhysioBank data. How the profiles were constructed, as well as simulation and parameter estimation techniques will be discussed. As the profile of the patients receiving these devices diversifies, it becomes necessary to update the tools used in the V&V structure used to properly assess these new devices. The aforementioned mock circulatory loop, and accompanying computational model, deliver the combined V&V toolset needed to address this new range of questions on safety assurance for a widening scope of use for these devices.
机译:临床证据表明左心室辅助装置(LVAD)接受者呈现不同的病理生理学和心脏功能队列。在该患者组中确保设备安全性和适当性能的挑战代表了条件的范围和解决方案中的挑战。此外,这些个体的心血管系统对可能触发LVAD的不安全操作条件的事件非常敏感:突然的姿势变化(例如落下),药物诱导的心动过速等。开发适当的计算设计工具和反射体外测试系统的反射性设计师在开发周期早些时候在设计中阐明更多负债。来自临床出版物的模拟循环回路的条件,详细描述了针对各种患者类和事件序列确定的心血管参数。设计了健康成人,充血性心力衰竭成人,健康老年,充血性心力衰竭老年和健康儿科的发达的曲线。型材是从发布的临床指标和Physiobank数据的参数估计开发的。如何构建配置文件,以及将讨论模拟和参数估计技术。由于接收这些设备的患者的简档,所以有必要更新用于正确评估这些新设备的V&V结构中使用的工具。上述Mock循环循环和附带的计算模型,提供所需的组合V&V工具集,以解决关于这些设备的使用范围的安全保证的新规定的新问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号