ESTIMATION OF THE INFLUENCE OF DEW CONDENSATION ON ANNUAL ENERGY GENERATION OF A CONCENTRATOR PV SYSTEM: ANALYSIS OF DATA OVER TWO YEARS

机译:凝结水对聚光光伏系统年发电量的影响估算:过去两年的数据分析

获取原文
获取外文期刊封面目录资料

摘要

In our previous analysis, using data from June 2004 to May 2005, we found that the annual energy generation of our concentrator photovoltaic (CPV)system was reduced by 1.2% by dew condensation. To clarify the influence of dew condensation on the energy generation, the present study performedadditional analysis using new data from °Ctober 2005 to September 2006, and compared the results to those of the previous analysis. The °Ccurrence of dewcondensation was derived from daily curves of the module efficiency and fill factor of the CPV system. The daily energy generation of the system wasestimated by correcting the measured values of the module efficiency to the ideal value for the same month. Because the module efficiency of CPV systemsusing three-junction cells is strongly influenced by seasonal variations in the spectrum of direct solar irradiance, ideal daily efficiency curves were createdeach month using data measured for days with clear skies. It was found that the reduction in annual energy generation of the CPV system was 2.0%,whereas it was 1.2% in the previous study.
机译:在我们之前的分析中,使用2004年6月至2005年5月的数据,我们发现聚光光伏(CPV)每年产生的能量 结露使系统减少了1.2%。为了阐明结露对能量产生的影响,本研究进行了 使用2005年10月至2006年9月的新数据进行进一步分析,并将结果与​​先前分析的结果进行比较。 °露水的发生 冷凝是从CPV系统的模块效率和填充因子的日曲线得出的。该系统每天的发电量为 通过将模块效率的测量值校正为当月的理想值进行估算。因为CPV系统的模块效率 使用三结电池会受到直接太阳辐射光谱的季节性变化的强烈影响,因此创建了理想的日效率曲线 每个月使用在晴朗的天空中测得的天数数据。发现CPV系统的年发电量减少了2.0%, 而在先前的研究中为1.2%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号