METHODOLOGY FOR DETERMINATION OF 110/35 kV AND 110/20 kV SUBSTATION REVITALIZATION ORDER

机译:测定110/35 kV和110/20 kV变电站恢复顺序的方法

获取原文

摘要

Currently all power distribution companies are in the period of their development characterized by large number of sites in operation of all types of voltage levels, which are older than 30 years, and many of them even older than 40 years. With investing in building new sites there is an emerging need for revitalization of old sites which still have a significant role in the distribution network. There is a large number of these sites and investment funds are not sufficient for contemporaneous revitalization, it is necessary to develop a methodology which would insure optimized order of investments. Criteria for determination of revitalization order have been divided in three groups. The first group consists of operation indices derived from: 1. age of site components, 2. number and duration of outages, 3. operation problems, 4. load of transformers and power equipment, 5. partially done reconstructions, 6. maintenance costs The second group are regulatory criteria which are derived from: 7. damage caused by undelivered electrical energy, 8. distributor penalties because of low quality of electrical energy The third group consists of indices which show the importance and perspective of observed sites and are derived from: 9. estimation of substation importance within the network, 10. future energy perspective of the site. 11. readiness of MV network (applied only for 110/35 kV) It is accepted that every criterion has the same weight so that the maximum value of one influential factor is 10 points. The order of sites is obtained by adding the values of influential factors together, so that the sum can not be greater than 100 (110 for transformer substations-TS 110/35 kV). In the end we observe a test of usage of determined criteria in example of 15 substations owned by Elektrovojvodina.
机译:目前,所有的配电公司都在其发展的阶段,特征大批各类电压等级,分别是30岁以上的经营场所的,其中许多超过40年,甚至更老。随着建设新的网站上投入有旧的网站仍然具有分销网络的显著作用的振兴的新需求。有大量的这些网站和投资资金都不足以振兴同期,有必要开发一种将确保最优化的投资顺序的方法。测定振兴秩序的标准已在三组被划分。第一组由衍生自操作指数:1.年龄部位组分,2号和断电的持续时间,3.操作问题,4.变压器和电力设备的负荷,5部分完成重建,6的维护费用的第二组是其衍生自监管标准:7.损伤引起的未传递的电能,8.分配器惩罚,因为电能的第三组由指数其显示的重要性和观察到的站点的角度和从衍生的低质量: 9.的变电站重要性估计网络内,该网站的10未来能源的观点。 11. MV网络的准备(只适用于35分之110千伏)被接受的是每标准具有相同的权重,使得一个影响因素的最大值为10分。位点的顺序是通过添加的影响因素的值一起获得的,以使得总和不能大于100(110,用于变电站-TS35分之110千伏)。最后,我们观察到的实施例的由Elektrovojvodina拥有15个变电站中确定的标准使用量的测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号