首页> 外文会议>European Conference on Power Electronics and Applications >Verification of the applicability of an RF-signal-based detection method for partial discharges on inverter-fed random wound stator windings in a low-voltage induction motor
【24h】

Verification of the applicability of an RF-signal-based detection method for partial discharges on inverter-fed random wound stator windings in a low-voltage induction motor

机译:验证基于射频信号的检测方法在低压感应电动机中的逆变器供电的随机缠绕定子绕组上的局部放电的适用性

获取原文

摘要

Partial discharges (PD) are widely known to occur in medium- and high-voltage applications. Recently, it has been observed that owing to the use of modern variable frequency converters, an environment that contributes to partial discharges is also found in low-voltage motors. Low-voltage machines are vulnerable to partial discharges because their winding insulation is not designed to withstand the phenomenon. As the number of inverter-driven systems is growing, the PD become a critical reliability issue. Therefore, methods to measure the phenomenon are required for the purposes of product development and maintenance. In this paper, detection of partial discharges in random wound low-voltage induction motors is studied by applying a radio-frequency-signal-based measurement setup for online partial discharge measurements.
机译:众所周知,局部放电(PD)发生在中压和高压应用中。近来,已经观察到,由于使用了现代的变频器,在低压电动机中也发现了导致局部放电的环境。低压电机很容易发生局部放电,因为其绕组绝缘并未设计成能够承受这种现象。随着逆变器驱动系统数量的增长,PD成为关键的可靠性问题。因此,为了产品开发和维护,需要测量现象的方法。在本文中,通过将基于射频信号的测量设置用于在线局部放电测量,研究了随机缠绕低压感应电动机中的局部放电检测。

著录项