首页> 外文会议>International Conference on Environment and Electrical Engineering >An improved modelling and construction of power transformer for controlled leakage inductance
【24h】

An improved modelling and construction of power transformer for controlled leakage inductance

机译:控制漏电电流变压器的改进建模与施工

获取原文

摘要

In this work, a transformer with increased leakage inductance for the soft switched power applications is presented as a practical solution by constructing a transformer with good control over the leakage inductance. An analytical reluctance based model is presented, which accurately predicts the leakage inductance. With the presented approach, a transformer is designed with a leakage inductance varying between 3-7μH. Increasing the efficiency and improving the power density has been the main focus of power electronics researchers in the recent years. In this regards, transformers with increased leakage inductance are becoming more popular in order to accomplish different soft switching concepts and for improving the power density.
机译:在这项工作中,通过构造具有良好控制的变压器,将具有增加的软交换电源应用的漏电电感的变压器作为实用的解决方案,通过构造具有良好的漏电感。提出了一种基于分析磁阻的模型,其精确地预测漏电感。利用所提出的方法,变压器设计,漏电电感在3-7μH之间变化。提高效率和提高功率密度是近年来电力电子研究人员的主要重点。在这方面,具有增加的泄漏电感的变压器变得越来越受欢迎,以便实现不同的软切换概念和提高功率密度。