首页> 外文会议>IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives >Circulating current minimization and current sharing control of parallel boost converters based on Droop Index
【24h】

Circulating current minimization and current sharing control of parallel boost converters based on Droop Index

机译:基于下垂指数的并联升压转换器的循环电流最小化和均流控制

获取原文

摘要

This paper investigates the relationship between current sharing difference and circulating current for two parallel connected dc-dc converters. In the proposed algorithm a new figure-of-merit called Droop Index is introduced, which is a function of normalized current sharing difference and losses in the output side of the converters. This algorithm minimizes the circulating current and current sharing difference between the converters. Although there may exist a trade-off between current sharing difference and voltage regulation, the proposed droop index algorithm gives better performance and low voltage regulation. The detailed analysis and design procedure are explained for two dc-dc boost converters connected in parallel. The effectiveness of proposed method is verified using MATLAB simulation.
机译:本文研究了两个并联的DC-DC转换器的均流差异与循环电流之间的关系。在提出的算法中,引入了一种新的品质因数,称为下降指数,它是归一化均流差和转换器输出侧损耗的函数。该算法使转换器之间的循环电流和均流差异最小化。尽管可能会在电流共享差异和电压调节之间进行权衡,但所提出的下垂指数算法却提供了更好的性能和低压调节。详细说明了两个并联的DC-DC升压转换器的分析和设计过程。利用MATLAB仿真验证了所提方法的有效性。