Based on the characteristic of 300 MW power station boiler four-tube leakage, the knowledge library of four-tube leakage fault was established. A new method of diagnosing four-tube leakage using threshold value principle and maximum membership principle was proposed. This method presents fault distance, fault-free radius, distance of fault threshold value, and could be visualized into geometry form. Diagnosis example shows that this new method has high accuracy when it is used for diagnosing four-tube leakage. This kind of geometry form is conducive to reveal the fault law and the links between various faults.
机译:基于300 MW电站锅炉四管漏电的特点,建立了四管泄漏故障的知识库。提出了一种使用阈值原理诊断四管泄漏的新方法和最大隶属原理。该方法呈现故障距离,无故障半径,故障阈值距离,并且可以可视化为几何形状。诊断示例表明,当它用于诊断四管泄漏时,这种新方法具有高精度。这种几何形式有利于揭示故障法和各种故障之间的联系。