首页> 外文会议>International conference on materials engineering and automatic control >Experimental Study on Detection of Local Damage of Concrete Beam End Based on EMI Technique
【24h】

Experimental Study on Detection of Local Damage of Concrete Beam End Based on EMI Technique

机译:基于EMI技术检测混凝土梁端局部损伤的实验研究。

获取原文

摘要

Nondestructive detection evaluation technique which based on the electro-mechanical impedance (EMI) method is widely used for structure health monitoring (SHM).The arrangement of piezoelectric transducer (PZT) includes two types,surface-mounted and embedded.A lot of researches have been done about two kind of transducer based on EMI method,however the effect of two types on the same damage condition requires to be researched deeply.Therefore,the objective of this investigation is comparing the effect of two kind types of PZT in detecting local damage of concrete beam end.An experiment was set up to detect local damage of the beam by EMI method with both embedded and surface-mounted PZT.The experiment result shows that EMI method is available to detect local damage of concrete beam end.The surface-mounted PZT is more sensitive to local damage of concrete beam end,meanwhile surface-mounted PZT is more vulnerable to the environment and other factors.
机译:基于机电阻抗(EMI)方法的无损检测评估技术被广泛用于结构健康监测(SHM)。压电换能器(PZT)的布置包括表面安装和嵌入式两种。基于EMI方法对两种换能器进行了研究,但两种类型对相同损伤条件的影响需要深入研究。因此,本研究的目的是比较两种类型的PZT在检测局部损伤中的作用。建立了通过嵌入式和表面安装的PZT的EMI方法检测梁局部损伤的实验。实验结果表明EMI方法可用于检测混凝土梁端部局部损伤。壁挂式PZT对混凝土梁端部局部损伤更敏感,而壁挂式PZT更易受环境和其他因素的影响。