According to the mechanical failure of Gas Insulated Switchgear (GIS) in the earthquake will cause a great loss to the power system. This paper, by using the three-dimension design software to build a geometric model of 420 kV GIS, by using the finite element analysis method to make the mode analysis, and then acquired structural frequencies and mode features of the GIS, and by using spectral analysis to get the stress distribution and structure deformation in the case of IX degree earthquake based on it. Through the simulation result of this model, the structure of the maximum stress occurs at the bracket where connected bus, and the maximum stress is 17.5Mpa that far less than the yield limit that is 235MPa. The maximum deformation occurs in the middle of the bus, and the maximum deformation is only 0.86 mm/m that comply with the requirements of the bus deformation is less than 3 mm/m. The results can provide a reference for the seismic reliability analysis of the high-voltage switchgear equipment.
机译:根据气体绝缘开关设备(GIS)在地震中的机械故障,将对电力系统造成巨大损失。本文利用三维设计软件建立了420 kV GIS的几何模型,利用有限元分析方法进行了模态分析,进而获得了GIS的结构频率和模态特征,并利用频谱以此为基础,得到IX级地震时的应力分布和结构变形。通过该模型的模拟结果,最大应力的结构出现在连接母线的支架上,最大应力为17.5Mpa,远小于屈服极限235MPa。最大变形发生在母线中间,最大变形仅为0.86mm / m,符合母线变形要求小于3mm / m。研究结果可为高压开关设备的抗震可靠性分析提供参考。