This paper summarizes the analysis of loss of coolant accident (LOCA) frequencies in support of a risk-informed (RI) evaluation of Generic Safety Issue (GSI) 191 for the South Texas Project Electric Generating Station (STPEGS) Units 1 and 2. The STP RI-GSI 191 Closure Study investigates the size and location of loss of coolant accidents (LOCAs) more finely than in traditional PRAs in order to assess the risk of debris formation during the LOCAs that could interfere with the operation of the emergency core cooling systems (ECCSs) or inhibit coolant flow through the core during the recirculation phase after a LOCA. The size and location of the break could influence the amount and chemistry of debris formation and the timing and need for actions to initiate or terminate containment sprays and recirculation cooling. This application requires the capability to estimate LOCA frequencies as a function of break size at each location within the Class 1 pressure boundary with due regard to the proper characterization and quantification of uncertainties.
机译:本文总结了冷却剂事故损失(LOCA)频率的分析,以支持对南德克萨斯项目发电站(STPEGS)1号和2号机组的通用安全问题(GSI)191进行风险评估(RI)评估。 STP RI-GSI 191封闭研究比传统PRA更加精细地调查了冷却剂事故(LOCA)的大小和位置,以评估LOCA期间可能会干扰应急堆芯冷却系统运行的碎屑形成风险(ECCS)或抑制冷却剂在LOCA之后的再循环阶段流过堆芯。破裂的大小和位置可能会影响碎片形成的数量和化学性质以及时间和启动或终止安全壳喷淋和再循环冷却的动作的必要性。此应用程序需要能够根据1级压力边界内每个位置处的断裂尺寸来估计LOCA频率,同时要适当考虑不确定性的正确表征和量化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号