A SCREENING METHODOLOGY FOR CLIMATIC EVALUATION OF THE COOLING POTENTIAL OF NIGHT VENTILATION IN BUILDINGS

机译:建筑夜间通风冷却潜势的气候评估筛选方法学

获取原文

摘要

Night ventilation is a well known strategy for passive cooling of residences and small commercial buildings. The building's thermal mass can be cooled at night by ventilating the inside of the space with the relatively lower outdoor air temperatures, thereby lowering indoor temperatures during the warmer daytime period. Numerous experimental and theoretical studies have shown the effectiveness of the method to significantly reduce air conditioning loads or improve comfort levels in those climates where the night time ambient air temperature drops below that of the indoor air. One could develop/adapt computer programs with detailed mathematical component models to simulate and evaluate the performance of night ventilation strategies in a specific location for a particular building. A more basic problem is to develop a methodology whereby potential designers can screen various climatic locations and regions in order to perform a preliminary evaluation of which months of the year are good candidates for implementing such a scheme. Only after completion of such a phase is a detailed evaluation warranted for specific buildings. In this paper, effectiveness of night ventilation is quantified by a parameter called the Discomfort Reduction Factor (DRF) which is the index of reduction of occupant discomfort levels during the day time from night ventilation. Two different thermal network models which provide such insights are evaluated. Daily and monthly DRFs are calculated for two climate zones and three building heat capacities for the whole year. It is verified that night ventilation is effective in seasons and regions when day temperatures are between 30 °C and 36 °C and night temperatures are below 20 °C. The accuracy of these preliminary screening models may be lower than using a detailed simulation program but the loss in accuracy in using such tools is more than compensated by the insights provided, along with better transparency in the analysis approach and results obtained.
机译:夜间通风是住宅和小型商业建筑被动冷却的众所周知的策略。可以通过夜间以相对较低的室外空气通风空间内部的方式来冷却建筑物的热量,从而在白天温暖的时候降低室内温度。许多实验和理论研究表明,在夜间环境空气温度低于室内空气温度的那些气候中,该方法可显着降低空调负荷或提高舒适度。可以开发/修改具有详细数学组件模型的计算机程序,以模拟和评估特定建筑物特定位置夜间通风策略的性能。一个更基本的问题是开发一种方法,使潜在的设计人员可以筛选各种气候位置和区域,以便对一年中的哪几个月是实施此方案的合适人选进行初步评估。仅在完成此阶段后,才需要对特定建筑物进行详细评估。在本文中,夜间通气的有效性通过称为“不适减少因子”(DRF)的参数进行量化,该参数是夜间通气白天白天乘员不适水平降低的指标。评估提供了这种见解的两种不同的热网络模型。计算全年两个气候区和三个建筑热容量的每日和每月DRF。经验证,夜间通风在白天温度介于30°C和36°C之间且夜晚温度低于20°C的季节和区域中是有效的。这些初步筛选模型的准确性可能低于使用详细的模拟程序,但使用此类工具所造成的准确性损失远远超过所提供的见解,而且分析方法和所得结果的透明度更高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号