首页> 外文会议>International conference on environmental odour monitoring and control >Can Electronic Noses be Used to Control Odour Abatement Measures in Sewers? - Approach by Testing 4 Multigas-sensor Systems under Realistic Conditions
【24h】

Can Electronic Noses be Used to Control Odour Abatement Measures in Sewers? - Approach by Testing 4 Multigas-sensor Systems under Realistic Conditions

机译:电子鼻可以用来控制下水道的除臭措施吗? -在实际条件下测试4种多气体传感器系统的方法

获取原文

摘要

Four Multigas-sensor systems (so called electronic noses or e-noses) with different sensors and configurations were tested over a period of 6 months at a sewer research plant of the Berliner Wasserbetriebe. They were exposed to different realistic process conditions. The objective was to analyse the applicability of electronic noses for the control of odour abatement measures in sewer systems. In order to describe the relation of the sensor signals to the odour, olfactometric and hydrogen sulphide (H2S) measurements were conducted. In the context of the data-mining process, the results were statistically evaluated. The best correlation coefficient for Linear Regression was 0.56 (e-nose D) whereas the results of Discriminant Analysis and Logistic Regression revealed that three of four e-noses are able to differentiate with regard to a level of 500 ou/m~3. Results on response time and repeatability showed a general practicability of e-noses for dosage control. The performance of the e-noses seems to depend on the system configuration (gas preparation, type of sensors).
机译:在Berliner Wasserbetriebe的下水道研究工厂对六个具有不同传感器和配置的Multigas传感器系统(所谓的电子鼻或电子鼻)进行了为期6个月的测试。他们面临着不同的现实过程条件。目的是分析电子鼻在下水道系统中控制气味消除措施的适用性。为了描述传感器信号与气味的关系,进行了嗅觉和硫化氢(H2S)测量。在数据挖掘过程中,对结果进行了统计评估。线性回归的最佳相关系数为0.56(电子鼻D),而判别分析和逻辑回归的结果表明,四个电子鼻中的三个能够区分500 ou / m〜3。响应时间和重复性的结果表明,电子鼻通常可用于剂量控制。电子鼻的性能似乎取决于系统配置(气体制备,传感器类型)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号