With the introduction of volatile renewable energy sources into the grid, the need for inexpensive ancillary service increases. We propose a method to provide ancillary service by using the flexibility of demand in commercial building HVAC (Heating, Ventilation, Air-Conditioning) systems. In particular, we show how a regulation command transmitted by a balancing authority can be tracked by varying the cooling demand in commercial buildings in real-time. A key idea here is the bandwidth limitation of the regulation signal, which allows the building's HVAC system to provide this service with little effect on the indoor climate. The proposed control scheme can be applied on any building with a VAV (Variable Air Volume) system and on-site chiller(s). Simple calculations show that the commercial buildings in the U.S. can provide 47 GW of regulation reserves in the frequency band f ∈ [1=(60 min);1=(3 min)] with virtually no change in the indoor climate, while meeting current ISO/RTO standards for regulation.
机译:随着挥发性可再生能源进入网格的推出,需要廉价的辅助服务的需求增加。我们提出了一种通过使用商业建筑HVAC(加热,通风,空调)系统的需求的灵活性提供辅助服务。特别是,我们展示了如何通过实时改变商业建筑物中的冷却需求来跟踪由平衡权传输的调节命令。这里的一个关键思想是调节信号的带宽限制,这使得建筑的HVAC系统提供了对室内气候影响几乎没有影响的这种服务。所提出的控制方案可以应用于VAV(可变空气量)系统和现场冷却器的任何建筑物。简单的计算表明,美国的商业建筑可以在频带f∈[1 =(60分钟); 1 =(3分钟)]中提供47 GW的调节储备。室内气候几乎没有变化,同时达到电流ISO / RTO规定标准​​。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号