With the rapid development of short range devices (SRD), it becomes critical to limit the electromagnetic radiation from the transmitters inside them. For both inductive loop coil transmitters and electric field transmitters, the conversion from magnetic field strength to radiated power in both near field and far field regions are discussed. Three power concepts, total radiated power (TRP), effective isotropic radiated power (EIRP) and effective radiated power (ERP) are clarified. Two concerns in current European Telecommunications Standards Institute (ETSI) and Australian / New Zealand StandardTM (AS/NZS) standards regarding SRD transmitter magnetic field strength or ERP / EIRP limits in the frequency range of 9 kHz to 30 MHz are addressed, formulae to convert from magnetic field strength to EIRP are derived.
机译:随着短距离器件(SRD)的快速发展,将电磁辐射限制在它们内部的变送器中来说至关重要。对于两个电感回路线圈发射器和电场发射器,讨论了在近场和远场中的磁场强度转换到近场区域和远场区域的辐射功率。三个功率概念,总辐射功率(TRP),有效各向同性辐射功率(EIRP)和有效辐射功率(ERP)。目前欧洲电信标准研究所(ETSI)和澳大利亚/新西兰标准的两个问题 tm (AS / NZS)关于SRD发射器磁场强度或ERP / EIRP限制的标准,频率范围为9kHz至30MHz,得到从磁场强度转换为EIRP的公式。