首页> 外文会议>Corrosion conference and expo;Corrosion 2012 >EFFECT OF TEMPERATURE ON WET CO_2 CORROSION OF 3Cr PIPELINE STEEL
【24h】

EFFECT OF TEMPERATURE ON WET CO_2 CORROSION OF 3Cr PIPELINE STEEL

机译:温度对3%Cr管线钢湿CO_2腐蚀的影响

获取原文

摘要

For their superior CO_2 corrosion resistance and relatively low cost, the new generation of low Cr (3 to 5%) bearing steels seem to be a good choice to meet the demand of preventing wet CO_2 corrosion of sub-sea wet gas pipelines. The data of extensive laboratory assessment and field experience have confirmed that low Cr bearing steels have an improved corrosion performance when immersed in CO_2 containing solutions, while the resistance to wet CO_2 corrosion has not been clarified. In this paper the effect of temperature on wet CO_2 corrosion of 3%Cr pipeline steel was investigated. Wet CO_2 corrosion environment in sub-sea wet gas pipelines was simulated in a high temperature and high pressure autoclave. Aseries of experiments were carried out at wet gas temperature of 30~90°C, while the cooling temperature was kept relatively low to provoke water condensation on the surface of coupons, ranging from 10°C to 30°C. The corrosion rate was determined by weight loss measurement. Scanning Electron Microscope (SEM) and Energy Dispersive Spectrum (EDS) were employed to analyze the corrosion scales.
机译:由于具有优异的抗CO_2腐蚀性和相对较低的成本,新一代低铬(3%至5%)轴承钢似乎是满足防止海底湿气管道湿CO_2腐蚀需求的好选择。大量实验室评估和现场经验的数据证实,低铬轴承钢浸入含CO_2的溶液时具有改善的腐蚀性能,而对湿式CO_2腐蚀的抵抗性尚不清楚。本文研究了温度对3%Cr管线钢湿式CO_2腐蚀的影响。在高温高压高压釜中模拟了海底湿气管道中潮湿的CO_2腐蚀环境。在30〜90°C的湿气温度下进行了一系列实验,同时保持较低的冷却温度,以使试样块表面凝结水,温度范围为10°C至30°C。通过失重测量来确定腐蚀速率。使用扫描电子显微镜(SEM)和能量色散谱(EDS)分析腐蚀垢。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号