首页> 外文会议>International congress on advances in nuclear power plants >Evaluation and improvement on external-hazard proof of JSFR fuel handling system
【24h】

Evaluation and improvement on external-hazard proof of JSFR fuel handling system

机译:JSFR燃料处理系统外部危险证明的评估与改进

获取原文
获取外文期刊封面目录资料

摘要

Responding to the the Fukushima Dai-ichi nuclear power plant (1F-NPP) accident, the earthquake and the tsunami proof of the fuel handling system (FHS) in Japan sodium-cooled fast reactor (JSFR) is studied. In the earthquake proof estimation, the margin of seismic resistance against the earthquake of the 1F-envelop condition and the sloshing behavior in the EVST is estimated. In terms of the tsunami proof, the scenario to lead fuel subassemblies into the stable cooling state and the potential of the cooling system is introduced in case of loss of the emergency power supply. As a result, it is clear that JSFR FHS originally could already be prepared to have the potential to prevent the release of radioactive material.
机译:研究了日本燃料处理系统(FHS)的福岛傣族核电站(1F-NPP)事故(1F-NPP)事故,地震和海啸证明钠冷却的快速反应器(JSFR)。在地震证明估计中,估计了抗逆转率的地震抗震率和EVST中的晃动行为的地震抗性。就海啸证明而言,在损失应急电源的情况下,引入了将燃料子组件引入稳定冷却状态的情况和冷却系统的电位。结果,很明显,最初可以准备好的JSFR FHS有可能防止放射性物质的释放。