This paper presents a reduced fan noise method, with increased fan-benefit analysis of various performances. The experimental approach adopts changes in the outlet in the form of two fans (flat tongue and a V-Type tongue plate) in order to measure the noise under the two forms of value and volume of supply air fan, shaft power consumption, operating current, and static pressure. The results showed that the tongue plate and the V-plane tongue plate noise between the value of the measurement location of 6.7 in the tongue plate in the plane below the noise level is about V-tongue plate 1 ~ 1.5dB (A). Air flow rate testing showed that the flat plate and the V-Type tongue plate between the tongue plate V-Type flow rate value, the measurement location of 3.4 in the tongue plate in the plane was more than the V-Type flow rate tongue plate 5 to 5.5%. Shaft power testing of measurement model 3, and measurement model 4, showed that the tongue plate in the plane V-tongue plate was more than 8%, 5%. The measurement models 3 and 4 and 5 showed more than the V-Type plane tongue plate 1%, 2.7%, and 2.6%. The measurement models 6 and 8 showed that, the flat tongue plate is less than the V-tongue plate of 2.9% and 2.3%. Static pressure testing showed that the flat tongue plate in particular measurement models (3,4,8,9), the static value of V-tongue plate than the 11.1% higher, respectively, 9%, 4.3%, and 3.7%. The results summarized above suggest that, in the specific measurement points, when parallel to the tongue plate the V-tongue board has better performance.
机译:本文提出了一种减少风扇噪声的方法,并增加了对各种性能的风扇效益分析。实验方法采用两个风扇(扁平舌和V型舌板)形式的出口变化,以便在送风风扇的值和体积,轴功率消耗,工作电流这两种形式下测量噪声,以及静压力。结果表明,舌板与V平面舌板之间的噪声的测量位置值在舌板6.7以下的噪声水平以下,约为V舌板的1〜1.5dB(A)。空气流量测试表明,平板与V型舌板之间的V型舌板的V流量值,测量平面中舌板3.4的位置要大于V型舌板的流量5至5.5%。测量模型3和测量模型4的轴功率测试表明,平面V型舌板中的舌板分别大于8%,5%。测量模型3、4和5显示比V型平面舌板多1%,2.7%和2.6%。测量模型6和8显示,平舌板比V舌板小2.9%和2.3%。静压测试表明,在特殊测量模型的平舌板(3、4、8、9)中,V舌板的静值比V型舌板高11.1%,分别为9%,4.3%和3.7%。上面总结的结果表明,在特定的测量点上,与舌板平行时,V舌板具有更好的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号