首页> 外文会议>2011 IEEE 57th Holm Conference on Electrical Contacts >The Effect of Mechanical Parameters of Switch-Type Contact on Relay Operation Characteristics
【24h】

The Effect of Mechanical Parameters of Switch-Type Contact on Relay Operation Characteristics

机译:开关型触点的机械参数对继电器动作特性的影响

获取原文

摘要

Electric arc erosion during contact break/make cause contact resistance degradation, material transfer, non-closing and non-opening, above failure modes affect relay operation characteristics greatly. A relay model testing device which could simulate relay parameters of: initial contact force between N.C. contacts, contact gap and N.O. over-travel mechanical parameters assembly was used to study arc erosion. During breaking and closing operation, contact resistance, pick-up/release voltage, pick-up/release/arc duration were recorded explicitly during test. The optimal matching mechanical parameters assembly of switch-type contact was determined by test results comprehensively. Therefore the contradiction between reducing arc duration and lower bouncing time was solved in maximum extent. The conclusions drawn in this paper are meaningful for optimization of mechanical parameters of switch-type contact in relay.
机译:触点断开/闭合过程中的电弧腐蚀会导致触点电阻降低,材料转移,不闭合和不断开,上述故障模式会极大地影响继电器的工作特性。可以模拟继电器参数的继电器模型测试设备:N.C.触点之间的初始接触力,接触间隙和N.O.超行程机械参数装配用于研究电弧腐蚀。在断开和闭合操作期间,在测试过程中明确记录了接触电阻,拾取/释放电压,拾取/释放/电弧持续时间。综合测试结果确定了开关型触头的最佳匹配机械参数组合。因此,最大程度地解决了缩短电弧持续时间与缩短弹跳时间之间的矛盾。本文得出的结论对于优化继电器中开关式触头的机械参数具有重要意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号