摘要

The aim of this study was to investigate the mechanical power of the ankle plantar flexion. The investigated power of the ankle plantar flexion would help to improve effectively the FES walking system using the ankle plantar flexion for patients and aged people in slow walking. The subjective pain by electrical stimulation sometimes becomes the burden to use the FES system. We also investigated the relationship between the mechanical power in ankle plantar flexion by electrical stimulation and the subjective pain. We developed the device to measure the ankle movement by electrical stimulation against load resistance torque. The device consisted of pads to support a single lower leg, a rotational footplate with a large pulley and a vertical weight to generate the load resistance torque, and a monophasic electrical stimulator via surface electrodes. Our results showed the proportional relationship between the mechanical power of the ankle plantar flexion and the subjective pain by electrical stimulation. To generate the same level in the ankle plantar flexor power 2.75W under the maximum voluntary exertion, the subjective pain by electrical stimulation exceeded 70, which means the feeling of crying at the Face Pain Scale. This result would help the better design of the FES walking system using the ankle plantar flexion for patients and aged people.
机译:这项研究的目的是调查踝plant屈的机械动力。研究的脚踝power屈力量将有助于使用慢速行走的患者和老年人有效地改善使用脚踝plant屈的FES步行系统。电刺激引起的主观疼痛有时会成为使用FES系统的负担。我们还研究了电刺激引起的踝plant屈机械动力与主观疼痛之间的关系。我们开发了一种通过电刺激对抗负载扭矩来测量踝关节运动的装置。该装置由支撑单个小腿的垫片,带大滑轮的旋转踏板和产生负载阻力扭矩的垂直配重以及通过表面电极的单相电刺激器组成。我们的研究结果显示,踝plant屈的机械动力与电刺激引起的主观疼痛之间存在比例关系。为了在最大自愿运动下产生相同水平的踝足屈肌功率2.75W,通过电刺激产生的主观疼痛超过70,这意味着在面部疼痛等级上哭泣的感觉。该结果将有助于为患者和老年人使用脚踝plant屈更好地设计FES步行系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号