首页> 外文会议>International conference on structural mechanics in reactor technology >RESOLVING OF VIBRATION MATTER ON FEED-WATER PIPING OF KOLANPP
【24h】

RESOLVING OF VIBRATION MATTER ON FEED-WATER PIPING OF KOLANPP

机译:KOLANPP进水管道中振动问题的解决

获取原文

摘要

This paper describes resolving an operational vibration problem of a feed-water (RL) piping located in the Turbine Hall of Kola Nuclear Power Plant (Units 3 and 4) with the help of high viscous dampers technology. Intensive vibration of these lines raised concerns in actual operation state of the plant and piping safety especially prior to power capacity upgrading of the Kola 3 and 4. Power upgrading is associated with an increase of working media flow in piping and corresponding increase of piping vibration might lead to exceeding recommended and threshold levels.The investigation covers the following items: 1.3D vibration measurement and walkdown of all vibrating RL-lines; 2.Piping finite element models development; 3.Simulation of dynamic excitation causing piping vibration close to measured one; 4.Development and implementation of protective measures. As a result of this work the minimal optimum number of high viscous dampers and their location along the lines were determined and the dampers were installed at the piping. VD type dampers of different size and construction were used. Finally, the substantial reduction of RL piping vibration has been achieved providing more safety and extending service life for pipelines and their support systems.
机译:本文介绍了借助高粘性阻尼器技术解决位于可乐核电站涡轮机大厅(3号和4号机组)的给水(RL)管道的运行振动问题。这些管线的强烈振动引起了工厂实际运行状态和管道安全性的问题,特别是在可乐3和4的功率容量升级之前。功率升级与管道中工作介质流量的增加相关,并且管道振动可能相应增加。调查涉及以下项目:1.3D振动测量和所有振动RL线的下移; 2.管道有限元模型开发; 3,模拟动态激励引起管道振动接近实测值之一; 4.制定和执行保护措施。作为这项工作的结果,确定了高粘度阻尼器的最小最佳数量及其在管路中的位置,并将阻尼器安装在管道上。使用了不同尺寸和结构的VD型阻尼器。最后,已经实现了RL管道振动的大幅降低,从而为管道及其支撑系统提供了更高的安全性并延长了使用寿命。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号