Possible failure modes of a prestressed concrete containment structures (PCCS) under the action of internal pressure are hoop tension; bending plus membrane stress at extreme fiber at wall-raft junction; shear near the edge and fixture on basement; and punching shear near large penetrations like airlocks. Amongst these, hoop tension at principally membrane region is reported to be the predominant one. The paper assesses the reliability of PCCS against hoop tension failure adopting first order second moment method of level-2 reliability analysis. The performance function, g (.), was formulated on the basis of standard design format of prestressed concrete containment structure for hoop tension induced by internal pressure. Three basic variables considered are internal pressure, ultimate strength of prestressing tendons and compressive strength of concrete. Short-term as well as time dependent long-term prestressing losses are taken into account in formulating g (.). Both epistemic and aleatory uncertainties associated with basic variables are considered. It is observed from the analysis results that reliability of a prestressed concrete containment structure deteriorates with age. It is also noted that uncertainties associated with ultimate strength of prestressing cable have maximum effect on failure probability where as that due to internal pressure and compressive strength of concrete have moderate and negligible effects respectively. Rational estimation of prestressing loss is very important for safety of the containment structure over the entire operating life.
机译:在内压作用下预应力混凝土容器结构(PCC)的可能失效模式是箍张力;在壁式筏交界处的极端纤维处弯曲加上膜应力;剪切在地下室的边缘和夹具附近;和冲压剪切像气闸等大的渗透。其中,据报道,主要膜区域的箍张力是主要的旋转张力。本文评估了采用第2级可靠性分析的第一阶第二矩法对箍张力故障进行PCCS对箍张力故障的可靠性。在预应力混凝土容纳结构的标准设计格式的基础上配制了性能功能G(。)。考虑了三种基本变量是内部压力,预应力肌腱的最终强度和混凝土的抗压强度。在制定G(。)时,考虑到短期以及时间依赖的长期预应力损失。考虑了与基本变量相关的认知和蜕膜不确定性。从分析结果观察到,预应力混凝土容纳结构的可靠性随着年龄而恶化。还有注意的是,与预应力电缆的最终强度相关的不确定性对失效概率的最大影响在其中由于内部压力和混凝土的压缩强度分别具有中等和可忽略的效果。对预应力损失的合理估算对于整个经营寿命的安全结构安全非常重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号