摘要

This paper presents experimental study for direct radiant floor heating system with air-source heat pump utilizing R22. An experimental platform was established, and thermal comfort of the heating system was analyzed from floor temperature, vertical temperature field, relative humidity, operation temperature and average radiation temperature, radiation asymmetry, PMV (Predicted Mean Vote) and PPD (Predicted Percent Dissatisfied). It shows that the indoor heat load can be well met as the output capacity of ASHP runs at 30%. When the heating system steadily runs, thermal comfort is very perfect. Finally calculating the values of PMV and PPD index, the results point out that PMV is about −0.7 ∼ −0.17, and PPD is 5.58%∼15.49%, which could well meet the requirements of thermal comfort in China (PPD ⩽ 20%, −1.5
机译:本文介绍了利用R22的空气源热泵直接辐射地板采暖系统的实验研究。建立了一个实验平台,并从地板温度,垂直温度场,相对湿度,运行温度和平均辐射温度,辐射不对称性,PMV(预测的平均投票)和PPD(预测的不满意百分比)分析了加热系统的热舒适性。结果表明,当ASHP的输出功率达到30%时,室内热负荷就可以很好地满足。当加热系统稳定运行时,热舒适性非常完美。最终计算出PMV和PPD指数,结果表明PMV约为-0.7〜-0.17,PPD为5.58%〜15.49%,可以很好地满足中国的热舒适性要求(PPD⩽20%, −1.5