摘要

This paper presents a new method for minimizing of voltage stress across devices in Z-source inverter. Both the dc boost and the ac output voltage of the Z-source inverter have been controlled using neural network controllers. The capacitor voltage of Z-source network has been controlled linearly in order to improve the transient response of the dc boost control of the Z-source inverter. The peak value of the line to line ac output voltage is used to control and keep the ac output at its desired value. A modified space vector pulse-width-modulation method is also applied to control the shoot-through duty ratio for boosting dc voltage. This modified method lets the dc voltage stress across the inverter switches be minimized. The new method for minimizing of voltage stress is verified by simulation results.
机译:本文提出了一种最小化Z源逆变器中器件两端的电压应力的新方法。 Z源逆变器的直流升压和交流输出电压均已使用神经网络控制器进行了控制。为了改善Z源逆变器的直流升压控制的瞬态响应,已经对Z源网络的电容器电压进行了线性控制。线到线交流输出电压的峰值用于控制交流输出并将其保持在所需的值。还采用了改进的空间矢量脉宽调制方法来控制直通占空比,以提高直流电压。这种改进的方法可以使逆变器开关两端的直流电压应力最小。仿真结果验证了最小化电压应力的新方法。

著录项