首页> 外文会议>FLOMEKO 2010;International flow measurement conference >Extended Measurement Range of Vortex Flow Meter in High Turbulent Range
【24h】

Extended Measurement Range of Vortex Flow Meter in High Turbulent Range

机译:高涡流范围内涡街流量计的扩展测量范围

获取原文

摘要

It is known that a vortex signal is fundamentally related to the fluid flow velocity. When, a vortex flow meter operates at a low flow velocity, the vortex signal is weak, which has been discussed by several researchers in recent years. Subsequently, when a flow meter operates at a high flow velocity, the vortex signal is superimposed on additional signals, making it difficult to extract the true vortex signal. Both problems directly influence the measurement range of a vortex flow meter. The investigation of the vortex signal in high turbulent range is rarely mentioned in literature, and is the focus of this work. A typical vortex flow meter has been optimized and its measuring range has been extended up to 55%.
机译:众所周知,涡旋信号基本上与流体流速有关。当涡街流量计在低流速下运行时,涡街信号微弱,这已在近几年得到了一些研究人员的讨论。随后,当流量计以高流速运行时,涡旋信号被叠加在附加信号上,使得难以提取真实涡旋信号。这两个问题都直接影响涡街流量计的测量范围。在高湍流范围内对涡旋信号的研究在文献中很少提及,并且是这项工作的重点。典型的涡街流量计已经过优化,其测量范围已扩展到55%。