首页> 外文会议>Proceedings of the 6th German Microwave Conference >Helix-shaped CRLH-TL sensor for inhomogeneties detection for pneumatic conveyed pulverized solids
【24h】

Helix-shaped CRLH-TL sensor for inhomogeneties detection for pneumatic conveyed pulverized solids

机译:螺旋形CRLH-TL传感器,用于气态输送粉状固体的不均匀性检测

获取原文

摘要

This paper presents an application of a Composite Right/Left-Handed (CRLH) Transmission Line resonator for a compact mass flow detector that is able to detect inhomogeneous flows. In this concept, series capacitors and shunt inductors are used to synthesize a medium with simultaneously negative permeability and permittivity — the so called metamaterial. The helix shape of the cylindrical CRLH-TL sensor offers the possibility to detect flow inhomogeneities within the pipeline which can be used to correct the detected massflow rate. A prototype was realized and tested in a dedicated measurement setup to prove the concept.
机译:本文提出了一种复合式右手/左手(CRLH)传输线谐振器在紧凑型质量流量检测器中的应用,该检测器能够检测非均匀流。在这个概念中,串联电容器和并联电感器用于合成同时具有负磁导率和介电常数的介质,即所谓的超材料。圆柱形CRLH-TL传感器的螺旋形状为检测管道内的流量不均匀性提供了可能性,可用于校正检测到的质量流量。在专用的测量装置中实现并测试了原型,以证明这一概念。