首页> 外文会议>Pacific structural steel conference >Behavior of the Tube-gusset Connection Using 600MPa High-strength Steel
【24h】

Behavior of the Tube-gusset Connection Using 600MPa High-strength Steel

机译:600MPa高强度钢管-角撑板连接的行为

获取原文

摘要

While the recent high demand for high rising buildings has led to the development of high-performance and high strength steels, the requirements for structural-performance steel for building have been raised as engineers recog nize the potential damage that an earthquake can wreak on a tall building. Many studies on high-strength steels have explored such need, but in case of hollow section, appropriate design equations are needed because the design equations limit the maximum yield stress up to 360MPa in the design code KBC 2009. This study is carried out the experiment test on strength of tube-gusset connection. It is also performed to investigate the behavior and strength of tube-gusset connection through comparing the experimental results and FEA using 600MPa circular hollow. This study analyses tube-gusset connection applied moment &- shear force and compares experimental values with analyt ical values for evaluating the applicability of current design equations. Current design equation is estimated to 68% ~129%.
机译:尽管最近对高层建筑的高需求导致了高性能和高强度钢的发展,但随着工程师意识到地震可能对高层建筑造成的潜在损害,对建筑物的结构性钢的要求也有所提高。建筑。许多有关高强度钢的研究都探讨了这种需求,但在空心截面的情况下,需要适当的设计方程式,因为设计方程式将最大屈服应力限制在设计规范KBC 2009中,最大屈服应力高达360MPa。测试管-角撑板连接的强度。通过比较实验结果和使用600MPa圆形空心管的有限元分析,还可以研究管-角撑板连接的性能和强度。本研究分析了管-角撑板连接施加的力矩和剪切力,并将实验值与分析值进行比较,以评估当前设计方程的适用性。目前的设计方程估计为68%〜129%。