首页> 外文会议>International Conference on Advanced Computer Control;ICACC 2010 >Application of Linear Frequency Modulation Pulse Compression in Air-coupled Ultrasonic Testing
【24h】

Application of Linear Frequency Modulation Pulse Compression in Air-coupled Ultrasonic Testing

机译:线性调频脉冲压缩在空气耦合超声测试中的应用

获取原文

摘要

Effective signal processing technology should be used to improve signal-to-noise ratio in air-coupled ultrasonic testing, because of there is feeble signal and low signal-to-noise ratio. Pulse compression of linear frequency modulation could enhance system's signal to noise ratio and distance resolution effectively. Principle of linear frequency modulation pulse compression is introduced, including of designing and accomplishing of matching filter. The relationship between pulse compression parameters and testing result is analyzed. The affect of exciting mode to ultrasonic signal and pulse compression to signal-to-noise ratio are researched by comparing experiment results. Air-coupled ultrasonic C-scan testing system based on pulse compression is accomplished, and the effectiveness of pulse compression method is testified by ultrasonic imaging results.
机译:由于空气微弱的信号和低的信噪比,在空气耦合超声测试中应使用有效的信号处理技术来提高信噪比。线性调频的脉冲压缩可以有效地提高系统的信噪比和距离分辨率。介绍了线性调频脉冲压缩的原理,包括匹配滤波器的设计和实现。分析了脉冲压缩参数与测试结果之间的关系。通过比较实验结果,研究了激励方式对超声信号的影响以及脉冲压缩对信噪比的影响。完成了基于脉冲压缩的空气耦合超声C扫描测试系统,并通过超声成像结果验证了脉冲压缩方法的有效性。