首页> 外文会议>2010 Asia Pacific Conference on Circuit and Systems >Chest compression depth measurement using IRUWB for CPR (cardiopulmonary resuscitation)
【24h】

Chest compression depth measurement using IRUWB for CPR (cardiopulmonary resuscitation)

机译:使用IRUWB进行CPR(心肺复苏)的胸部按压深度测量

获取原文

摘要

An Impulse based ultra-wide band (UWB) transceiver was designed using 130nm CMOS technology for a Bio-ranging system to improve the quality of cardiopulmonary resuscitation (CPR). It is developed to measure the depth of chest compression in CPR which is crucial factor for CPR quality using IR-UWB technology. The transmitter is composed of impulse generator and power amplifier (PA) operating at the center frequency of 530MHz and bandwidth of 140MHz. The Receiver is composed of a low noise amplifier (LNA), a mixer/integrator and a flash ADC. The fully integrated transceiver system operates with 1.5V supply voltage and occupies 7.6 mm2. The measurement results show that the proposed transceiver provides the spatial resolution within ±1.3cm while consuming total power of 35.6mW.
机译:基于130nm CMOS技术设计了基于脉冲的超宽带(UWB)收发器,用于生物测距系统,以提高心肺复苏(CPR)的质量。它被开发用来测量心肺复苏中胸部按压的深度,这是使用IR-UWB技术对心肺复苏质量至关重要的因素。发射器由脉冲发生器和功率放大器(PA)组成,功率放大器(PA)的中心频率为530MHz,带宽为140MHz。接收器由低噪声放大器(LNA),混频器/积分器和闪存ADC组成。完全集成的收发器系统在1.5V电源电压下工作,占用7.6 mm 2 。测量结果表明,所提出的收发器提供了±1.3cm的空间分辨率,同时消耗了35.6mW的总功率。