On the basis of researching quartz crystal measurement standards and methods based on the direct transmission method, quartz crystal, an electrical parameter model of a π-network and its effect to the measurement accuracy of electrical parameters of quartz crystal have been analyzed, and a measurement technique of quartz crystal series resonant frequency parameters has been researched. Based on the research, the measurement system has been designed. The results of measurement experiments show that when the measurement system is in the 200MHz frequency range, the measurement error of the series resonant frequency is less than 2ppm, and the measurement error of the series resonant resistance is less than 10% (or 2Ω).
机译:在研究基于直接透射法的石英晶体测量标准和方法的基础上,分析了石英晶体,π网络电参数模型及其对石英晶体电参数测量精度的影响,并进行了测量。研究了石英晶体的谐振频率参数技术。在此基础上,设计了测量系统。测量实验结果表明,当测量系统在200MHz频率范围内时,串联谐振频率的测量误差小于2ppm,串联谐振电阻的测量误差小于10%(或2Ω)。