Pulse wave velocity (PWV) is a marker of arterial stiffness and may permit continuous, non-invasive, and cuff-less monitoring of blood pressure. Here, robust PWV estimation was sought by application of system identification to proximal and distal arterial waveforms. In this approach, the system that optimally couples the proximal waveform to the distal waveform is identified, and the time delay of this system is then used to calculate PWV. To demonstrate proof-of-concept, a standard identification technique was applied to non-invasive impedance cardiography and peripheral arterial blood pressure waveforms from six humans subjected to progressive reductions in central blood volume induced by lower body negative pressure. This technique estimated diastolic pressure with an overall root-mean-squared-error of 5.2 mmHg. For comparison, the conventional detection method for estimating PWV yielded a corresponding error of 8.3 mmHg.
机译:脉搏波速度(PWV)是动脉僵硬度的标志,可以连续,无创且无袖带地监测血压。在此,通过将系统识别应用于近端和远端动脉波形,寻求鲁棒的PWV估计。在这种方法中,确定了将近端波形最佳耦合到远端波形的系统,然后将该系统的时间延迟用于计算PWV。为了证明概念验证,将标准识别技术应用于非侵入式阻抗心动图和来自六个人的下肢动脉血压波形,这些人由于下体负压而导致中心血容量逐渐减少。该技术估计舒张压的总均方根误差为5.2 mmHg。为了比较,用于估计PWV的常规检测方法产生了8.3mmHg的相应误差。