首页> 外文会议>19th International Conference on Electrical Machines >Influence of mounting temperature probes on the excitation winding on its temperature field
【24h】

Influence of mounting temperature probes on the excitation winding on its temperature field

机译:温度探头对励磁绕组温度场的影响

获取原文

摘要

Accurate and reliable information about the temperature of the synchronous generator excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram. For good estimation of a position and the hot spot temperature it was decided to mount 19 temperature probes on one pole of the 6-pole, 400 kVA, 50 Hz synchronous generator. Due to a large number of the probes and because the probes should be glued with the metal epoxy it was assumed that mounting of the probes will disrupt the temperature field of the excitation winding. To get the answer to this question the excitation winding resistance was measured before and after mounting the probes, in a hot and a cold state. Temperature rise can be estimated if the resistance ratio in the hot and the cold state is known. The paper also addresses the analysis of the measurement accuracy.
机译:有关PQ图表中由励磁绕组过热引起的动态极限的确定,需要有关同步发电机励磁绕组热点温度的准确而可靠的信息。为了更好地估计位置和热点温度,决定将19个温度探头安装在6极,400 kVA,50 Hz同步发电机的一个极上。由于存在大量的探针,并且由于探针应与金属环氧树脂胶粘,因此假定探针的安装会破坏励磁绕组的温度场。为了得到这个问题的答案,在热和冷状态下,在安装探头之前和之后都测量了励磁绕组的电阻。如果已知热态和冷态下的电阻比,则可以估计温度上升。本文还讨论了测量精度的分析。