首页> 外文会议>24th International Symposium on Discharges and Electrical Insulation in Vacuum >Development of a combined opening switch for the project of generator on inductive storages
【24h】

Development of a combined opening switch for the project of generator on inductive storages

机译:为感应储能发电机项目开发组合式断开开关

获取原文

摘要

The article proposes a fundamentally new approach to the problem of breaking high currents of 100kA or more. The vacuum discharger and the vacuum interrupter differ significantly in the rate of electric strength recovery, size of electrode erosion and etc. This is due to the difference in the type of the discharge. In the report considered we suggested that to align these values the current I should be closed through the spark gap prior to moving the electrodes of the vacuum interrupter; at this its value is above the initial by ΔI (ΔI-current, ΔI/I0 ∼5÷10·10). The excess ΔI-current flows through the vacuum interrupter, but in the reverse direction. In the course of moving the electrodes apart, the ΔI-current falls to zero with a time constant t=L/R, where L and R are the inductance of the contour (vacuum interrupter- spark gap) and resistance of the discharge of the discharge gap, respectively. This makes it possible to quickly recover the electric strength of the gap between the contacts, substantially reduce the electrode erosion and significantly decrease the breaking voltage of the ΔI-current. At the final stage the discharge of the countercurrent battery recovers the vacuum strength of the discharge gap.
机译:本文提出了一种全新的方法来解决100kA或更高的高电流中断问题。真空放电器和真空灭弧室在电强度恢复率,电极腐蚀尺寸等方面有显着差异。这是由于放电类型的不同所致。在考虑的报告中,我们建议要对齐这些值,在移动真空灭弧室的电极之前,应先通过火花隙闭合电流I;在此值下,其值比初始值高ΔI(ΔI电流,ΔI/ I 0 〜5÷10·10 -)。过量的ΔI电流流经真空断路器,但方向相反。在移动电极的过程中,ΔI电流以时间常数t = L / R降为零,其中L和R是轮廓的电感(真空灭弧室-火花隙)和电极放电的电阻。放电间隙分别。这使得可以快速恢复触点之间的间隙的电强度,充分减少电极腐蚀并显着降低ΔI电流的击穿电压。在最后阶段,对流电池的放电恢复了放电间隙的真空强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号