DCM boost PFC converter with high input PF

机译:具有高输入PF的DCM升压PFC转换器

获取原文

摘要

Discontinuous current mode (DCM) boost power factor correction (PFC) converter features zero-current turn-on for the switch, no reverse recovery in diode and constant frequency operation, however, the input power factor (PF) is relatively low when the duty cycle is constant in a half line cycle. This paper derives the expressions of the input current and PF of DCM boost PFC converter, and based on which, a variable duty cycle control is proposed so as to improve the PF to nearly unity in the whole input voltage range. A method of fitting the duty cycle is further proposed for simplifying the circuit implementation. Besides a higher PF, the proposed variable duty cycle control achieves a lower output voltage ripple and a higher efficiency over the constant duty cycle control. The experimental results from a 120 W universal input prototype are given to verify the effectiveness of the proposed method.
机译:不连续电流模式(DCM)升压功率因数校正(PFC)转换器具有开关的零电流导通,二极管无反向恢复和恒定频率工作的特性,但是,当负载占空时,输入功率因数(PF)相对较低周期在半线周期中是恒定的。本文推导了DCM升压PFC变换器的输入电流和PF的表达式,并在此基础上,提出了一种可变占空比控制,以在整个输入电压范围内将PF提高到接近统一。为了简化电路实现,还提出了一种适合占空比的方法。除了较高的PF之外,与恒定占空比控制相比,所提出的可变占空比控制还实现了较低的输出电压纹波和较高的效率。给出了来自120 W通用输入原型的实验结果,以验证所提出方法的有效性。