To date, the skin effect has not been considered in the analysis of network fault response and the design of protection systems for DC networks. However, the naturally high resonant frequencies of some modern marine and aerospace electrical networks under electrical fault conditions suggest that skin effect should be investigated more closely. The studies reported in this paper compare the system fault response for both a conventional circuit model and a model incorporating the skin effect. The results show a noticeable difference, demonstrating that in some cases the skin effect should be considered for studies of this nature. The paper builds upon these findings by investigating the impact on protection system operation, making recommendations for associated modelling and simulation practices.
机译:迄今为止,在网络故障响应分析和DC网络保护系统设计中尚未考虑趋肤效应。但是,某些现代海洋和航空网络在电故障条件下的自然高共振频率表明,应更仔细地研究趋肤效应。本文报道的研究比较了常规电路模型和包含趋肤效应的模型的系统故障响应。结果显示出明显的差异,表明在某些情况下应考虑对皮肤的这种性质的研究。本文通过调查对保护系统运行的影响,并为相关的建模和仿真实践提出建议,以此为基础。

著录项