首页> 外文会议>5th IET International Conference on Power Electronics, Machines and Drives >Sensor and open-phase fault detection and isolation for three-phase AC drives
【24h】

Sensor and open-phase fault detection and isolation for three-phase AC drives

机译:三相交流变频器的传感器和缺相故障检测与隔离

获取原文

摘要

This paper deals with an on-line fault detection and isolation method for three-phase AC drives. The method is based on the detection of the stator current positive- and negative-sequence fundamental components expressed in the stationary αβ reference frame. These components allow calculating two fault indices used for the detection and isolation of an open-phase fault and a sensor fault, i.e. a disconnected sensor. The decision criterion is based on the CUSUM algorithm. The method includes a phase locked-loop performing the frequency adaptation needed to achieve fault detection on a wide speed range and even during speed transient. An experimental validation of the proposed method showing its effectiveness is carried out.
机译:本文提出了一种三相交流变频器的在线故障检测与隔离方法。该方法基于对静止αβ参考系中表示的定子电流正序和负序基本分量的检测。这些组件允许计算用于检测和隔离断相故障和传感器故障(即传感器断开)的两个故障指标。决策标准基于CUSUM算法。该方法包括锁相环,该锁相环在宽速度范围内甚至在速度瞬变期间执行实现故障检测所需的频率自适应。实验证明了该方法的有效性。