摘要

Light load efficiency of high frequency DC/DC converters used in portable electronic devices is very important for extending lifetime of batteries. This paper proposes to use large-range gradually changed nonlinear inductors with adaptive on time control to improve the light load efficiency not only in DCM, but also in CCM. Loss reduction is demonstrated by calculating loss of a conventional converter and a converter with the proposed method. Multi-permeability magnetic cores based on LTCC technology are advanced to realize the nonlinear inductors. An analytic model is set up to show the design of inductor. A two permeability inductor prototype is fabricated. Its inductance is 91nH at full load, 53nH at no load.
机译:便携式电子设备中使用的高频DC / DC转换器的轻载效率对于延长电池寿命非常重要。本文提出使用具有自适应导通时间控制的大范围逐渐变化的非线性电感器,以提高DCM和CCM中的轻载效率。通过计算常规转换器和采用所提出方法的转换器的损耗,可以证明损耗的降低。提出了基于LTCC技术的多磁导磁芯,以实现非线性电感器。建立了一个解析模型来展示电感的设计。制造了两个磁导率电感器原型。它的电感在满载时为91nH,在空载时为53nH。