首页> 外文会议>Bioinformatics and Biomedical Engineering , 2009. ICBBE 2009 >Study on the Pre-Treatment for Landfill Leachate by Fenton Reagent
【24h】

Study on the Pre-Treatment for Landfill Leachate by Fenton Reagent

机译:Fenton试剂预处理垃圾渗滤液的研究。

获取原文

摘要

Landfill leachate pre-treatment was studied by Fenton reagent composed of FeSO4ldr7H2O and H2O2. The different effect factors of CODcr were studied, such as pH value, Fenton reagent under different dosages, the molar ratio of ferrous ion to H2O2 and reaction time. The results indicated: when the pH value was 3.0, the dosages of H2O2 was 0.25 mol, FeSO4ldr7H2O and H2O2 in the molar proportion was 10 to 1 and reaction time was 1.5 hour, the higher CODcr removal efficiency was obtained, reached 64.7%.
机译:Feent 4 ldr7H 2 O和H 2 O 2 组成的Fenton试剂研究了垃圾渗滤液的预处理。研究了CODcr的不同影响因素,如pH值,不同剂量的Fenton试剂,亚铁离子与H 2 O 2 的摩尔比以及反应时间。结果表明:当pH值为3.0时,H 2 O 2 的用量为0.25 mol,FeSO 4 ldr7H 2的用量 O和H 2 O 2 的摩尔比为10:1,反应时间为1.5小时,获得较高的CODcr去除率,达到64.7% 。